Over recent years, there has been an increasing trend towards utilisation of renewable sources of energy. In order to meet this demand, Gorenje has developed the KGV combined water reservoir, which can be used in the central heating systems in combination with solar collectors and other energy sources.
KGV water reservoirs are the result of many years of research and experience in the field of water heaters. Manufactured from high-quality steel sheet, the KGV is enamelled and provided with a magnesium protective anode.
Inside, one or two smoothbore heat exchangers have been built in for fast heating and high permanent capacity.
Insulation manufactured from hard CFC-free polyurethane with an average thickness of 57 mm provides high thermal insulation.
Option: HEAT PUMP installation.

  • floor vertical version
  • one or two highly efficient heat exchangers enable preparation of hot water:
    • with central heating system,
    • with solar collector,
    • with a combination of different sources.
  • possibility of subsequent installation of an electrical heater on the side flange
  • possibility of subsequent installation of an electrical heater to the connecting bushing
  • possibility of subsequent installation of a heat pump on the side flange
  • thermometer
  • coating color of your choice
  • 2 year general warranty, 3 year warranty for the tank

 

Properties >>>

ModelKGV 200-1KGV 300-1 KGV 300-2
Volume (l)200285 280
Dimensions of Connections   
Total height (mm)11501550 1550
Outside diameter (mm)650650 650
Connections to the supply networkG 1G 1 G 1
Net / gross weight (kg)82/90/282112/120/397 134/142/417
Technical Characteristics   
Enamelled steel tank  •
Magnesium protective anode  •
Average thickness of insulation (mm) 5757 57
Degree of protection against humidity IP 21IP 21 IP 21
Connecting bushing G 6/4•  •
Side flange 180 mm• •  •
Heat Exchanger below   
Dimensions of connectionsG 1G 1 G 1
Exchanger area (m²)0,851,45 1,45
Volume (l)5,3 9,1  9,1
Heat Exchanger above   
Dimensions of connections-- G 1
Exchanger area (m²)-- 0,90
Volume (l)- 5,7
Working pressure   
Water reservoir (bar)66 6
Heat exchanger (bar)1212 12
Max. Temperature   
Water reservoir (°C)8585 85
Heat exchanger (°C)120120 120
Option   
Instalation of an electrical heater to the connecting bushing •
Instalation of an electrical heater on the side flange •
Installation of a heat pump •
Transportation Data   
Packaging dimensions (mm)750 x 750 x 1350750 x 750 x 1750 750x750x1700
No. of pieces per truck (120 m³)6060 60

Dimensions >>>


KGV 300-2 with solar panels and central heating hot-water system

Key:

  1. Water heater
  2. Central heating hot-water system
  3. Solar panel
  4. Differential thermostat with sensors (T1, T2, T3, T4)
  5. Bypass pump
  6. Expansion tank
  7. Non-return valve
  8. Safety valve
  9. Air relief valve
  10. Fill/drain valve
  11. Reduction valve
  12. Outlet valve
  13. Stop valve
  14. Test unit
  15. Funnel outlet to the drain

KGV 200-1, 300-1 with central heating hot-water system

KGV 200-1, 300-1 with solar panels